import serial
import requests
import os
from dotenv import load_dotenv
import logging
import signal
import time
load_dotenv()
##########################################
#Logging
if os.environ['logging_level'] == "DEBUG":
loglevel = logging.DEBUG
elif os.environ['logging_level'] == "INFO":
loglevel = logging.INFO
logger = logging.getLogger('Power Monitor')
logger.setLevel(loglevel)
#Console Handler
ch = logging.StreamHandler()
ch.setLevel(loglevel)
#Formatter
formatter = logging.Formatter('[%(asctime)s] [%(levelname)s] %(message)s')
formatter.default_msec_format = None
ch.setFormatter(formatter)
if not logger.handlers:
logger.addHandler(ch)
##########################################
ntfy_token = os.environ['NTFY_Token']
device_name = os.environ['device_name']
shutdown_timer = int(os.environ['shutdown_timer'])
running = True
def handle_shutdown(signum, frame):
global running
logger.info("Received shutdown signal, exiting...")
running = False
signal.signal(signal.SIGTERM, handle_shutdown)
signal.signal(signal.SIGINT, handle_shutdown)
def main():
with serial.Serial(device_name, 115200, timeout=1) as ser:
shutdown_triggered = False
inverter_online = True
last_online = time.monotonic()
receiving_data = True
last_logged = -1
try:
while running:
line = ser.readline().decode(errors="ignore").strip()
if line != "" and not receiving_data:
receiving_data = True
logger.info("Serial data restored")
if line == "0":
if not inverter_online:
logger.info("Inverter restored")
inverter_online = True
last_online = time.monotonic()
elif line == "1":
if inverter_online:
inverter_online = False
logger.info("Running on UPS reserve")
elif line == "":
if receiving_data:
receiving_data = False
logger.warning("No serial data")
else:
logger.warning(f"Unexpected serial data: {line}")
if not inverter_online:
sec = int(time.monotonic() - last_online)
if sec % 10 == 0 and sec != last_logged:
logger.info(f"Offline for {sec}s")
last_logged = sec
if sec >= shutdown_timer:
shutdown_triggered = True
break
if shutdown_triggered:
logger.info(f"Inverter offline for {shutdown_timer} seconds")
try:
requests.post(
"https://ntfy.fieryeagle.org/Internet-Alerts",
data="Inverter offline, shutting down".encode("utf-8"),
headers={
"Title": "Hydrogen running on reserve power",
"Authorization": f"Bearer {ntfy_token}"
},
timeout=5
)
except Exception as e:
logger.error(f"Failed to send notification: {e}")
os.system("shutdown now")
else:
logger.info("Exited cleanly (service stop)")
except serial.SerialException as e:
logger.error(f"Serial device error: {e}")
raise
if __name__ == "__main__":